Encapsulated Steel Ventilated Raised Floor

Send Inquiry
Encapsulated Steel Ventilated Raised Floor
Details
The system combines enclosed steel panels with ventilated units to create an accessible underfloor plenum for conditioned air, power cables, and data lines. Solid and ventilated panels integrate within a single grid to match specific cooling and load requirements.
Category
Encapsulated Steel Raised Flooring
Share to
Description

Encapsulated Steel Ventilated Raised Floor

 

Steel Raised Access Flooring for Data Centers, Server Rooms and Technical Facilities
FINECO Encapsulated Steel Ventilated Raised Floor is a modular access flooring system designed for technical environments requiring underfloor air distribution, structural performance, and service accessibility.
The system combines enclosed steel panels with ventilated units to create an accessible underfloor plenum for conditioned air, power cables, and data lines. Solid and ventilated panels integrate within a single grid to match specific cooling and load requirements.

 

Key Product Advantages

 

Controlled Air Distribution: Directs conditioned air from the underfloor plenum to high-heat equipment zones.
Fully Encapsulated Steel Core: Enclosed steel structure provides a rigid, durable, and stable access surface.
Flexible Airflow: Configurable open areas and optional dampers support precise room-level air balancing.
High Load Capacity: Engineered to support heavy IT hardware, server racks, batteries, and maintenance traffic.

 

Panel Construction

 

FINECO is engineered as a complete, integrated access floor system rather than isolated vent tiles.
Top Finish: Optional anti-static HPL, conductive vinyl, PVC, or bare steel.
Steel Shell: Fully welded and encapsulated steel construction for high structural rigidity.
Ventilated Section: Precision perforations or grates designed for optimal airflow delivery.
Bottom Structure: Protective steel underside shielding the internal core.
Understructure: Heavy-duty adjustable steel pedestals and optional stringers ensuring finished floor stability.

 

Airflow & Cooling Specifications

 

Parameter

FINECO Specification

Panel Type

Perforated / Grated / Custom

Open Area

15% – 35% (Configurable)

Airflow Rate

Engineered to project static pressure

Airflow Control

Optional sliding dampers

Standard Size

600 × 600 mm

Airflow Direction

Vertical / Adjustable

 

Structural Load Performance

 

Engineered in compliance with global standards such as CISCA and EN 12825.

Parameter

Performance Benchmark

Concentrated Load

4,450 N – 6,670 N (Configurable)

Uniform Load

10 kN/m² – 23 kN/m² (Configurable)

Ultimate Load

> 3× Concentrated Load

Rolling Load

3,000 N – 4,500 N (10,000 cycles)

Deflection Class

Class A / Class B

 

Technical Specifications Summary

 

Item

Specification Details

Product Type

Steel Raised Access Floor System

Panel Size

600 × 600 mm

Panel Material

Fully Encapsulated Welded Steel

Electrical Resistance

10⁶ to 10⁹ ohms (Anti-static)

Fire Performance

Class A / Non-combustible core options

Pedestal Height Range

150 mm to 1,500 mm (Adjustable)

Primary Applications

Data Centers, Server Rooms, Telecom Hubs

 

Surface Finish Options

 

Anti-Static HPL: Durable decorative layer with controlled electrical properties for server rooms.
Conductive Vinyl: High static dissipation with simple maintenance for control facilities.
PVC Finish: Cost-effective, practical solution for technical equipment zones.

 

Pedestal & Understructure Support

 

Adjustable Steel Pedestals: Compensates for subfloor unevenness and establishes precise finished floor height (FFH).
Stringer System: Snap-on or bolted steel profiles providing lateral rigidity for high-load zones.
Service Cavity: Hidden, clean channel for power routing, network cabling, and HVAC lines.

 

Applications

 

Data Centers & Co-location Facilities: Balances high-density cooling with heavy structural support.
Server & Telecom Rooms: Organizes heavy cabling and delivers targeted rack cooling.
Command & Control Centers: Provides a stable, vibration-free environment for technical desks.

 

Installation Workflow

01/

Subfloor Preparation: Clean and seal the base concrete.

02/

Grid Layout: Mark pedestal positions according to engineering drawings.

03/

Height Adjustment: Level pedestals to establish the target FFH.

04/

Stringer Placement: Secure stringers for lateral stability (if specified).

05/

Panel Installation: Lay solid and ventilated tiles into the grid.

06/

Final Inspection: Check level alignment, stability, and airflow distribution.

Complete System Components

 

Ventilated & Solid Panels

Floor surface zoning.

Pedestals & Stringers

Core structural framework.

Airflow Dampers

Volume regulation valves.

Cable Grommets

Sealed pass-throughs for lines.

Access Lifters & Ramps

Maintenance tools and ADA transitions.

 

Quality Control & Compliance

 

Multi-Stage Inspection: Material checks, dimensional tolerances, flatness testing, and load verification.
Documentation: Mill test reports, technical drawings, and compliance records supplied per project requirements prior to dispatch.

 

Frequently Asked Questions

 

Q: What is an encapsulated steel ventilated raised floor?

A: A modular access flooring system using enclosed steel panels with engineered perforations to supply cooling air while concealing underfloor services.

Q: Can ventilated and solid panels be mixed?

A: Yes. They interlock seamlessly within the same 600 × 600 mm grid layout.

Q: Are airflow rates adjustable?

A: Yes, optional under-panel dampers regulate air volume.

Q: What international standards do you support?

A: Systems can be configured to comply with CISCA and EN 12825 specifications.

Q: Can FINECO provide engineering drawings and samples?

A: Yes, CAD drawings, data sheets, and project samples are available upon request.

Hot Tags: encapsulated steel ventilated raised floor, China encapsulated steel ventilated raised floor manufacturers, suppliers, factory

Send Inquiry