Suited for current facilities, FINECO's pvc raised access computer floor offers excellent durability, effortless cable organization, and unparalleled load-bearing capacity. Thanks to its modular design, quick installation and flexibility for reconfiguring are possible. It has anti-static and fire-resistant features, ensuring a safer, more structured environment. Great for data centers, offices, and industrial spaces-elevate efficiency and aesthetics with a lasting solution.
Product specification
|
Model |
Concentrated Load |
Impact Load |
Ultimate Load |
Uniform Load |
Rolling Load (N) |
||
|
LB |
N |
N |
N |
N/㎡ |
10 times |
10000 times |
|
|
FS800 |
800 |
3560 |
536 |
10680 |
16100 |
3560 |
2670 |
|
FS1000 |
1000 |
4450 |
670 |
13350 |
23000 |
4450 |
3560 |
|
FS1250 |
1250 |
5560 |
780 |
16680 |
33000 |
5560 |
4450 |
|
FS1500 |
1500 |
6660 |
1005 |
19980 |
34500 |
6675 |
5340 |
|
FS2000 |
2000 |
8900 |
1340 |
26700 |
46000 |
8900 |
7120 |
* According to CE& CISCA's recommended test procedures for Access Floors
600*600mm/24'*24' (610*610mm) available
Product feature and application
FINECO's pvc raised access computer floor offers strong and dependable solutions for contemporary infrastructure demands. Made from high-strength, anti-corrosion materials with fire-resistant coatings, these floors provide excellent load-bearing capacity and enduring durability. The modular design enables rapid installation, easy reconfiguration, and smooth access to underfloor utilities, boosting operational efficiency. Integrated cable management channels improve airflow and organize power/data cabling while reducing clutter. Perfect for challenging environments like data centers, industrial facilities, command control rooms, and laboratories, pvc raised floors ensure safety, flexibility, and adherence to international standards, supporting changing spatial needs with little maintenance.
Product details

FINECO's pvc raised access computer floor stands out with its precision-engineered details for optimal performance. ESD edge trims ensure seamless conductivity and static dissipation across the floor system. Each floor is treated with a stringent epoxy powder-coated anti-rust process, guaranteeing corrosion resistance in humid or harsh settings. Multiple anti-static laminate options (HPL, PVC, ceramic) provide customizable aesthetics while maintaining 10^4–10^9Ω surface resistance. Reinforced bolted stringers enhance structural stability, supporting point loads up to 890kg. Fire-rated cores meet ASTM E84 Class 1 standards. Optional gasket-sealed edges create air-tight compartments for clean room or pressurized situations, showcasing versatility across technical specifications.
Product Qualification

FINECO's pvc raised access computer floors are crafted to the highest standards of quality and durability, beginning with premium materials and precise manufacturing. Key components utilize high-grade ST14 and SPCC steels, known for their remarkable strength, corrosion resistance, and formability, ensuring structural integrity under demanding conditions.
Lightweight foam concrete is integrated to enhance performance, reducing overall weight while delivering top-notch thermal insulation, sound absorption, and eco-friendly attributes. The manufacturing process employs heavy-duty, high-tonnage presses to ensure uniform pressure and meticulous shaping, thereby eliminating material defects and guaranteeing dimensional accuracy.


The blend of advanced materials and industrial-grade equipment leads to products that regularly surpass industry standards for longevity, reliability, and operational excellence, fulfilling the most stringent customer expectations.
Shipping and Package


FAQ
Q: 1. How is a pvc raised access computer installed?
A: When installing, it usually entails leveling the subfloor, positioning the support pedestals, fixing the beams or stringers, and putting in place the floor panels. The height can be modified using the pedestals to meet specific requirements. Seams between the panels are sealed for airtightness and finished off with edge trim for safety.
Q: 2. How do I maintain a pvc raised access computer?
A: Regular scrutiny for loose panels and damaged supports is essential. Vacuuming or sweeping the underfloor space to eliminate debris is required. Avoid heavy point loads that exceed the rated capacity. Replace damaged panels promptly, and ensure good cable organization to prevent obstructions.
Q: 3. Can pvc raised access computer be adjusted after installation?
A: Yes. Adjustable pedestals allow for variations in height to accommodate new equipment or the rerouting of cables. The option to add or remove panels makes raised floors highly flexible in response to changing needs.
Q: 4. Can pvc raised access computer be installed over existing flooring?
A: Yes, PVC raised access computer floors can be directly installed over existing concrete, tiles, or carpeted surfaces, as long as the subfloor is level and structurally sound. This saves time and cost compared to removing the original floor.
Q: 5. How do I choose the right pvc raised access computer?
A: When opting for a raised floor, consider these factors:
●Operating environment: Including load requirements, anti-static requirements, and cleanliness requirements.
●Height: Determine according to wiring and ventilation requirements.
●Material properties: Such as wear resistance, fire resistance, and corrosion resistance.
●Budget and maintenance: Consider both the initial investment and long-term maintenance costs.
Hot Tags: pvc raised access computer floor, China pvc raised access computer floor manufacturers, suppliers, factory